HPLCThermoFisher / Dionex
UltiMate 3000
HPLC
ThermoFisher / Dionex
UltiMate 3000
Prix fixe hors TVA
10 000 €
État
Occasion
Emplacement
Borken 

Données de base
- Désignation de la machine:
- HPLC
- Fabricant:
- ThermoFisher / Dionex
- Modèle:
- UltiMate 3000
- État:
- d'occasion
Prix et localisation
Prix fixe hors TVA
10 000 €
- Emplacement:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Appel
Détails sur l'offre
- Identifiant de l'annonce:
- A22257747
- Numéro de référence:
- 24837
- Mise à jour:
- dernière mise à jour le 03.07.2026
Description
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Csdpfxszikcxs Aqqjri
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength:
L'annonce a été traduite automatiquement et des erreurs de traduction peuvent apparaître.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Csdpfxszikcxs Aqqjri
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength: